Eaton Power-Suppress 100
The Eaton Power-Suppress 100 Ultra-Isolator Noise Suppressors protect sensitive equipment against electrical noise disturbances. Using exclusive double shielding techniques, the Power Suppress 100 blocks all forms of electrical noise including RFI/EMI, over a broad range of frequencies.
ИБП Eaton

- ИБП для компьютеров и рабочих станций
- ИБП Eaton Protection Station (500 - 800 BA)
- Eaton 3S (550-700 ВА)
- Eaton Ellipse ECO (500-1600BA)
- Eaton 5E (500-2000BA)
- Eaton 5S (550 - 1500ВA)
- Eaton Ellipse PRO (650-1600 ВA)
- ИБП для сетевого и серверного оборудования
- Eaton 5SC (500 - 3000ВA)
- Eaton 5P (650 – 1550 ВA)
- Eaton 5PX (1500-3000 BA)
- E Series DX (1-20 кВА)
- Eaton EX (700 - 1500 BA)
- Eaton 9SX (700-3000 ВA) – замена 9130
- Eaton 9SX (5-11 кВА) – замена 9130
- Eaton 9PX (1-3 кВА)
- Eaton 9PX (5-22 кВА)
- Eaton 9E (6-20 кВА)
- Eaton 9155 (8 - 30 кВА)
- ИБП с двойным преобразованием для ЦОД и ответственной электроники
- Eaton 9355
- BladeUPS (12 - 60 кВт)
- Eaton 93PM (30-500 kВА)
- ИБП Eaton 91PS и 93PS (8-30 / 40 кВт)
- Eaton 93E (15 - 200 кВА)
- Power Xpert 9395P (250 - 1200 кВА)
- Промышленный ИБП
- Промышленный ИБП Eaton 9PHD (30–200 кВА)
- ИБП для морских судов и платформ
- Eaton 9SX Marine (1000-3000 BA)
- Eaton 9PX Marine (1500-3000 BA)
- Eaton 9155 Marine (8-30 кВА)
- Eaton 93PS Marine (8-40 kW)
- Power distribution (PDU)
- Модули распределения нагрузки (PDU)
- Managed
- Switched
- Metered Outlet
- Metered Input
- In-Line Metered
- Basic
- Eaton HotSwap MBP
- Eaton FlexPDU
- ATS 16 & ATS 30
Eaton Power-Suppress 100 – Technical Specifications


Electrical characteristics | |
Input voltage frequency | 120, 240, 480V*/60 Hz |
Common-mode noise | 140 dB @ 100 kHz |
Normal-mode noise | 65 dB @ 100 kHz |
Overload capacity | 600% for 1 cycle 300% for 30 seconds |
Dielectric strength | 2,500 Vac minimum |
Frequency | 60 Hz ±5% |
Impedance | 3-6% typical |
Efficiency | 93-97% typical |
Input voltage range | ±10% of nominal rated voltage |
Load regulation | 2-5% or less from no load to full load at unity power factor |
Harmonic distortion | Adds less than 1% THD, under linear loading |
Coil insulation | 200°C |
Temperature rise | 115°C max rise about a 40°C ambient, depending on model |
Electro-magnetic interference | <0.2 gauss @ 36 inches |
Environments | |
Audible noise | Less than 50 dBA measured at 3 feet from the noise suppressor |
Operating temperature | 0°C-40°C |
Storage temperature | -20°C-50°C |
Operating altitude | Up to 12,000 feet (without derating) |
Operating humidity | 95% relative (non-condensing) |
Standards | |
Safety agency | UL 1012, UL 1449, cUL Listed, ANSI/IEEE C57.12.91 Meets FCC Category A, IEEE C62.41 Category A3 |
Warranty | Two year warranty complete unit, five year warranty core and coil |
*480V available for 5 and 7.5 kVA models only
Plug & Receptacles Configuration Models
Rating | Input plug | Output receptacle |
500-1000 VA | 5-15P | 5-20R duplex |
1.8 kVA | L5-20P | 2 x 5-20R duplex |
2.4 kVA | L5-30P | 2 x 5-20R duplex |
Eaton Power-Suppress 100 Model Selection Guide
Part Number | Input voltages1 | Output voltages1 | Output VA2 | I/O interface (NEMA) | H x W x D, (in) | Weight (lb) |
Line-cord/receptacle models | ||||||
T100R-0500 | 120 | 120 | 500 | 5-15P / (1) 5-20R2 | 6.49 x 6.10 x 12.00 | 22 |
T100R-0750 | 120 | 120 | 750 | 5-15P / (1) 5-20R2 | 6.49 x 6.10 x 12.00 | 28 |
T100R-1000 | 120 | 120 | 1000 | 5-15P / (1) 5-20R2 | 6.49 x 6.10 x 12.00 | 31 |
T100R-1800 | 120 | 120 | 1800 | L5-20P / (2) 5-20R2 | 10.49 x 11.10 x 17.00 | 54 |
T100R-2400 | 120 | 120 | 2400 | L5-20P / (2) 5-20R2 | 10.49 x 11.10 x 17.00 | 58 |
Terminal style models | ||||||
T100H-0500 | 120/240 | 120/240 | 500 | Hardwired | 6.42 x 6.10 x 12.00 | 22 |
T100H-0750 | 120/240 | 120/240 | 750 | Hardwired | 6.42 x 6.10 x 12.00 | 28 |
T100H-1000 | 120/240 | 120/240 | 1000 | Hardwired | 6.42 x 6.10 x 12.00 | 31 |
T100H-1800 | 120/240 | 120/240 | 1800 | Hardwired | 10.28 x 11.10 x 17.00 | 54 |
T100H-2500 | 120/240 | 120/240 | 2500 | Hardwired | 10.28 x 11.10 x 17.00 | 58 |
T100H-5000 | 120/240 | 120/240 | 5000 | Hardwired | 10.28 x 11.10 x 17.00 | 86 |
T100H-50013 | 240/480 | 120/240 | 5000 | Hardwired | 10.49 x 11.10 x 17.00 | 92 |
T100H-7500 | 120/240 | 120/240 | 7500 | Hardwired | 10.28 x 11.10 x 17.00 | 116 |
T100H-75013 | 240/480 | 120/240 | 7500 | Hardwired | 10.28 x 11.10 x 17.00 | 111 |
Notes:
- Input and output voltages can be configured for either 120 Vac or 240 Vac, 240 Vac or 480 Vac, as indicated above.
- 500 VA to 7500 VA hardwired models will ship configured to 120V input and output voltage.
- Models T100H-5001 and T100H-7501 will ship configured to 240V input and output voltage.
Eaton Power-Suppress 100 – Features
- Traps unwanted harmonics
- Remove surge voltages and minimizes reflected THD
- Eliminates load generated feedback
- Available in both hardwired or line cord/receptacle models
- Fast and easy installation
- Long life operation
- Small footprint – saves valuable space
- Meets FCC Category A
- UL 1012, cUL, UL 1449
- Two-year, five-year warranty core & coil
Eaton Power-Suppress 100 – Documentation